Insulation/ CALCULATOR

Ventilation fan electricity

Estimate daily and period electricity use from the measured or rated supply and extract fan power.

Use measured input or product data at the selected operating point.
Enter zero for a system without a separate extract fan.
Use equivalent full-power hours if the fans modulate.
Choose the period being assessed.
Use the marginal tariff in any currency.
Combined fan input

70 W

Electricity per operating day

1.68 kWh/day

Electricity for the period

613.20 kWh

Estimated electricity cost

122.64 currency units

The entered power represents the selected operating point and the equivalent hours capture modulation. Filter loading, frost mode, standby power, controls and changing airflow can alter actual electricity use.

FROM ESTIMATE TO ACTION

Use the result, not just the number.

01

Match electrical power and measurement scope

Use electrical input in W for supply and extract fans at the same operating setting, not airflow, motor output or a control percentage. If a documented value already combines both fans, count it once in one power field and enter zero in the other; record that choice. Do not add component powers to the same combined reading. Separate any controls or heaters included by the meter from a fan-only estimate.

02

Calculate operating modes before extrapolating

35 + 35 = 70 W at 24 h/day gives 1.68 kWh/day and 613.2 kWh over 365 days, assuming unchanged operation. These are example inputs, not typical consumption. For changing modes, calculate each mode separately and add its energy: 70 W × 8 h + 140 W × 2 h = 0.84 kWh for that day. A fan-speed percentage is not automatically the same percentage of electrical power.

03

Keep energy, price and ventilation performance separate

At an entered price of 0.20 per kWh, 613.2 kWh costs 122.64 in that currency. Zero price makes calculated cost zero, not electricity use. Record the tariff basis and account for standing charges or time-dependent prices separately. Standby, controls and heaters may need separate measurement. This electricity total does not establish airflow, recovered heat, safe ventilation or the benefit of shortening operation.

Inputs to verify

Supply fan input power (W)
Use measured input or product data at the selected operating point.
Extract fan input power (W)
Enter zero for a system without a separate extract fan.
Operating hours per day (h/day)
Use equivalent full-power hours if the fans modulate.
Number of days (days)
Choose the period being assessed.
Electricity price (currency units/kWh)
Use the marginal tariff in any currency.

Continue your calculation