Electrical power/ CALCULATOR

Inverter running and motor-start screen

Compare one documented motor start plus other loads with derated continuous and surge inverter ratings.

Exclude the motor entered below.
Use documented or measured real running power.
Use total starting watts or a manufacturer-supported equivalent, not an assumed universal multiplier.
Use the applicable output rating at the intended temperature, voltage and power factor.
The rating must last at least as long as the documented motor start.
Allowance for operating condition and design margin; follow manufacturer limits.
Combined running requirement

1,300 W

Combined starting requirement

2,500 W

Allowed continuous output

2,700 W

Allowed surge output

5,400 W

Continuous-power margin

1,400 W

Starting-power margin

2,900 W

Interpretation:The simplified screen leaves 1,400 W of continuous margin and 2,900 W of starting margin. Confirm start duration, VA and battery-side limits.

One motor starts while all entered other loads remain steady. Watts are compared directly. The screen excludes VA, power factor, waveform compatibility, start duration, voltage dip, multiple starts, battery current limits, cable loss, inverter temperature and protection behaviour. The inverter and motor manufacturers must confirm compatibility.

FROM ESTIMATE TO ACTION

Use the result, not just the number.

01

Verify the inputs

Measure or document each input. If a value is only an estimate, record its source and test a conservative alternative.

02

Keep the calculation traceable

Save the input link or copied result together with the date, units and assumptions. A number without its inputs cannot be checked later.

03

Confirm the decision

Compare the estimate with the related guide, current product data and requirements that apply at your location before buying or building.

Inputs to verify

Other loads already running (W)
Exclude the motor entered below.
Motor running demand (W)
Use documented or measured real running power.
Motor total starting demand (W)
Use total starting watts or a manufacturer-supported equivalent, not an assumed universal multiplier.
Inverter continuous rating (W)
Use the applicable output rating at the intended temperature, voltage and power factor.
Inverter surge rating (W)
The rating must last at least as long as the documented motor start.
Usable rating allowance (%)
Allowance for operating condition and design margin; follow manufacturer limits.