Wells & water/ CALCULATOR

Well specific-capacity and pumping-level screen

Turn one stabilized pumping observation into specific capacity and a cautious linear screen for another flow.

Measure from one documented reference point after an appropriate recovery period.
Use the level at the stated test flow after the observation has stabilized sufficiently.
Measure flow during the same period as the pumping-level observation.
Keep close to the tested range; extrapolation becomes increasingly unreliable.
Use the installed intake depth from the same reference point.
Set from pump, well-construction and professional requirements.
Observed drawdown

6.00 m

Observed specific capacity

5.00 L/min/m

Linearly screened drawdown

8.00 m

Linearly screened pumping-level depth

20.00 m

Water-cover margin above intake

10.00 m

Interpretation:The linear screen leaves 10 m of water-cover margin above the protected intake zone. Confirm the target flow with a suitable pumping test.

The static and pumping levels share one reference, and the stated flow and level represent the same stabilized observation. The linear projection excludes nonlinear well loss, boundaries, delayed yield, seasons, interference and continuing drawdown. Use it only near tested conditions and never as proof of sustainable yield or safe pump setting.

FROM ESTIMATE TO ACTION

Use the result, not just the number.

01

Verify the inputs

Measure or document each input. If a value is only an estimate, record its source and test a conservative alternative.

02

Keep the calculation traceable

Save the input link or copied result together with the date, units and assumptions. A number without its inputs cannot be checked later.

03

Confirm the decision

Compare the estimate with the related guide, current product data and requirements that apply at your location before buying or building.

Inputs to verify

Static water-level depth (m)
Measure from one documented reference point after an appropriate recovery period.
Stabilized pumping-level depth (m)
Use the level at the stated test flow after the observation has stabilized sufficiently.
Measured test flow (L/min)
Measure flow during the same period as the pumping-level observation.
Flow to screen (L/min)
Keep close to the tested range; extrapolation becomes increasingly unreliable.
Pump-intake depth (m)
Use the installed intake depth from the same reference point.
Required water cover above intake (m)
Set from pump, well-construction and professional requirements.

Continue your calculation

Explore all calculators