Independent energy/ CALCULATOR

Hot-water tank recovery time

Estimate the energy, cost and ideal time needed to heat a stored volume between two temperatures.

Use the volume that actually needs reheating, not automatically the tank nameplate volume.
Use a realistic inlet or mixed tank temperature for the scenario.
Energy arithmetic does not determine a safe storage or delivery temperature.
Use sustained input available to water heating, after any power limiting or staging.
Useful heat entering the water divided by purchased energy during recovery.
Use your all-in energy price in any currency; the result uses the same currency.
Temperature rise

45.0 °C

Heat delivered to water

7.85 kWh

Required input energy

8.26 kWh

Energy cost per full recovery

1.65 currency units

Ideal recovery time

2.75 h

Ideal recovery time

165 min

Equivalent recovery rate

54.5 L/h

Interpretation:With no hot-water draw during recovery, the ideal heating time is about 2.75 hours. Verify the product recovery rating and available electrical power.

Uniform water temperature, constant heat capacity, constant input power, stated efficiency and a flat energy price. Tank stratification, thermostat deadband, heating-element staging, draw-off during recovery, pipe losses, standby loss and fixed tariff charges are excluded. Product recovery ratings and safe-temperature requirements govern final selection.

FROM ESTIMATE TO ACTION

Use the result, not just the number.

01

Keep input power separate from heat output

Enter sustained heater input in kW: 3000 W means 3 kW, not 3000. Use power available to water heating in this operating condition, not a whole-building supply rating. This model then applies the entered efficiency; entering useful heat output as input power would apply efficiency a second time. Enter 95 for 95%, not 0.95. The defaults are examples, not verified ratings for your heater.

02

Check the complete reheating scenario

Use the water volume actually reheated and final minus starting temperature. For 150 L from 10°C to 55°C, the rise is 45°C: about 7.85 kWh of heat and 8.26 kWh input at 95%. With 3 kW input this is 2.75 h, or about 165 min; at a tariff of 0.20 per kWh, energy alone costs about 1.65 in that currency. These temperatures and tariff illustrate arithmetic, not safe settings or a current price.

03

Treat recovery rate as an equivalent, not outlet flow

The example gives about 54.5 L/h for the same 45°C rise, not a measured tap flow or the available mixed shower volume. At unchanged volume, rise and efficiency, doubling input power halves ideal time but leaves input kWh and energy cost unchanged. The model has no draw-off during recovery, tank stratification, thermostat cycling or separately added standby losses. Use product recovery data and actual operating limits for selection; ideal time is not a guaranteed completion time.

Inputs to verify

Water volume to reheat (L)
Use the volume that actually needs reheating, not automatically the tank nameplate volume.
Starting water temperature (°C)
Use a realistic inlet or mixed tank temperature for the scenario.
Target water temperature (°C)
Energy arithmetic does not determine a safe storage or delivery temperature.
Sustained heater input power (kW)
Use sustained input available to water heating, after any power limiting or staging.
Heat delivered to water (%)
Useful heat entering the water divided by purchased energy during recovery.
Electricity price (currency units/kWh)
Use your all-in energy price in any currency; the result uses the same currency.

Continue your calculation